alpereninyeri
TREN

Hasselblad CFV II-50c vs Hasselblad H4D-50: read noise comparison

Hasselblad CFV II-50c

The Hasselblad CFV II-50c was measured at 9 ISO settings from ISO 100 to ISO 25600. Values are Bill Claff's (Photons to Photos) direct measurements from raw files.

At base ISO (100) read noise is 4.86 DN, or 3.7 electrons at the sensor. From ISO 800 up the camera is effectively ISO-invariant: raising ISO further doesn't meaningfully lower shadow noise. Settings above ISO 3200 don't change analog gain (digital push). Full well at base ISO is about 49,010 electrons; unity gain is around ISO 80.

Hasselblad H4D-50

The Hasselblad H4D-50 was measured at 5 ISO settings from ISO 50 to ISO 800. Values are Bill Claff's (Photons to Photos) direct measurements from raw files.

Hasselblad CFV II-50c vs Hasselblad H4D-50 read noise table

ISOHasselblad CFV II-50cHasselblad H4D-50
50–27.096
1004.85754.569
2006.727111.430
40011.158221.322
80019.698442.643
160036.002–
320066.718–
640066.718–
1280066.718–
2560066.718–

Popular comparisons

All cameras · Open the full tool

Alperen Kılıç · Read Noise

Data: Photons to Photos · © William J. Claff